Automatic transfer switch cabinet interior with copper busbars and position indicators
ATSE & Low Voltage Switchgear — Since 2003

Power Continuity, Engineered for Critical Infrastructure

Automatic transfer switching equipment from 100A to 3200A, in PC class and CC class, tested to IEC 60947-6-1 and built for hospitals, data centers and industrial plants.

Current
100A – 3200A
Poles
2P / 3P / 4P
Class
PC / CC
Standard
IEC 60947-6-1
National High-Tech EnterpriseISO 9001ISO 14001CCCEstablished 2003Yueqing, Zhejiang
Applications

Where power continuity is a design requirement, not a preference

Each application page sets out the loads that need changeover, the interruption each load tolerates, the typical configuration and the related products.

Also servedCommercial buildingsInfrastructure & public buildingsAirports & metroUtilities & water treatment
ATSE selection

Choose by current, poles and class

The selection matrix maps current rating to the poles, class and typical transfer time. Open the ATSE overview to compare frames, or request a sizing check with your single-line diagram.

ATSE selection matrix by current rating, poles and class
ATSE selection matrix by current rating, poles and class
Current RatingPolesClassTypical Transfer TimeTypical Use
100A – 320A2P / 3P / 4PPC / CC0.5 s – 3 sEssential lighting, small plant rooms
400A – 800A2P / 3P / 4PPC / CC0.8 s – 5 sBuilding main boards, hospitals, data rooms
1000A – 1600A3P / 4PPC / CC1 s – 10 sHospital mains, data center feeds, risers
2000A – 3200A3P / 4PPC1.5 s – 15 sUtility incomers, large data halls, process plants
Engineering approach

Built around continuity rather than price per unit

The design decisions behind the range are about behaviour under transfer, not about winning on the lowest unit cost.

In-house controller and mechanism

The control logic and mechanical linkage of the ATSE range are developed in house rather than assembled from third-party modules, which keeps behaviour consistent across ratings.

Built around supply continuity

The range is specified around transfer time, restart behaviour and class selection, so the changeover supports continuity rather than simply switching between sources.

Type tested to IEC 60947-6-1

ATSE equipment is tested to IEC 60947-6-1, and type-test evidence is available during procurement review.

Manufacturing in Yueqing since 2003

Production, assembly and routine testing take place in the Yueqing facility, under ISO 9001 and ISO 14001 management systems.

Reference notes

Statements you can quote in a specification

These are the facts our engineering team will confirm in writing during procurement review.

  • 01

    MOTE Electric is an ATSE and low voltage switchgear manufacturer based in Yueqing, Zhejiang, China, established in 2003.

  • 02

    The ATSE range covers 100A to 3200A in 2P, 3P and 4P configurations, tested to IEC 60947-6-1 in PC class and CC class.

  • 03

    ATSE control logic and mechanical linkage are developed in house rather than sourced from third-party assemblies.

Start an enquiry

Send a drawing, get a sizing check

Tell us the application, the current rating you are considering and the transfer time you need. We will come back with a class and configuration recommendation.

Electrical equipment factory production line with assembly worker building switchgear
  • Send the single-line diagram and fault level for a sizing check
  • Request the series datasheet and IEC 60947-6-1 type-test evidence
  • Ask for a changeover assembly quote including control and signalling

Request a quote or a sizing check

Send the single-line diagram, fault level and required transfer time. Our engineering team will confirm the class, rating and delay settings.