Automatic Transfer Switching Equipment (ATSE)

Dual power changeover equipment from 100A to 3200A, in 2-pole, 3-pole and 4-pole versions, PC class and CC class, tested to IEC 60947-6-1. Use the selection matrix to shortlist a frame, then open the series page for the full parameter table.

  • 01

    MOTE Electric automatic transfer switching equipment is tested to IEC 60947-6-1 and available from 100A to 3200A in PC class and CC class configurations.

  • 02

    The range is offered in 2-pole, 3-pole and 4-pole versions with adjustable transfer time per frame.

  • 03

    Selection follows current rating, pole configuration, class and the required transfer time for the loads served.

Selection matrix

Shortlist by current rating, poles and class

Each row maps a current band to the pole options, class availability and the typical transfer time used in that band.

ATSE selection matrix by current rating, poles and class
ATSE selection matrix by current rating, poles and class
Current RatingPolesClassTypical Transfer TimeTypical Use
100A – 320A2P / 3P / 4PPC / CC0.5 s – 3 sEssential lighting, small plant rooms
400A – 800A2P / 3P / 4PPC / CC0.8 s – 5 sBuilding main boards, hospitals, data rooms
1000A – 1600A3P / 4PPC / CC1 s – 10 sHospital mains, data center feeds, risers
2000A – 3200A3P / 4PPC1.5 s – 15 sUtility incomers, large data halls, process plants
Class selection

PC class or CC class

The class is a coordination decision. PC class relies on upstream protection to break fault current, while CC class includes an integral breaking element.

PC class and CC class compared
PC class and CC class compared
PropertyPC classCC class
Short-circuit making and carryingYesYes
Short-circuit breaking by the changeover deviceNo — relies on upstream deviceYes — integral breaking element
Typical useMain incomers with coordinated upstream protectionEquipment and sub-boards close to the source
Standard referenceIEC 60947-6-1IEC 60947-6-1

Confirm the class against the fault level

Where the changeover sits close to the transformer and the fault level is high, CC class is commonly specified. On main incomers with coordinated upstream protection, PC class is usual. Either way, the decision belongs to the short-circuit coordination study.

Datasheets and type-test evidence

Series datasheets and IEC 60947-6-1 type-test evidence are issued on request so the correct revision reaches your project file.

Request datasheet
FAQ

ATSE questions buyers ask us

Direct answers to the questions that come up most often during procurement.

What is the difference between PC class and CC class ATSE?

PC class carries and closes on short-circuit current but does not break it, relying on the upstream device. CC class includes an integral short-circuit breaking element, so the changeover itself is rated to break fault current.

How do I choose the current rating for an ATSE?

Start from the board design current and the restart behaviour of the largest load. For motor-heavy boards, restart current — not running current — decides the rating.

Does the ATSE comply with IEC 60947-6-1?

Yes. The ATSE range is tested to IEC 60947-6-1, and type-test evidence is available on request during procurement review.

Are 2-pole and 4-pole versions available across the range?

2-pole, 3-pole and 4-pole versions are available on the smaller frames, while the larger frames from 1000A upwards are supplied in 3-pole and 4-pole configurations.

Need the ATSE sizing method? Read the ATSE sizing guide for generator backup systems or contact info@motegrid.com with your single-line diagram.

Request an ATSE quote

Send the rated current, pole configuration, class preference and required transfer time. We will confirm the frame and delay settings.